MATERIAL SAFETY DATA SHEET

 

Product Name: DERŪ 736

Catalog Number: 21395

DOT Hazard Class: Not Hazardous

MSDS Updated: 9/16/05

 

Distributed By: Ladd Research

                         83 Holly Court

                         Williston, VT 05495

                         (802) 658-4961

 

HAZARDOUS COMPONENTS

                                                           CAS Number     Percent      Exposure Limits

epichlorohydrin-polyglycol                            9072-62-2               100         Not Available

        reaction product

 

PHYSICAL AND CHEMICAL DATA

Specific Gravity: 1.14

Vapor Pressure: 8 mm Hg @ 25EC

Solubility: Slightly soluble in water

Appearance and Odor: Viscous colorless to slightly yellow liquid

 

FIRE AND EXPLOSION HAZARD DATA

Flash Point: 338EF

Extinguishing Media: Foam, carbon dioxide, dry chemical

Special Fire Fighting Procedures: None

Unusual Fire and Explosion Hazards: None

 

HEALTH HAZARD DATA

Primary Routes of Entry: skin, eye

Skin: Minor irritation

Eye: Moderate irritation and transient slight to moderate corneal injury

 

EMERGENCY AND FIRST AID

Skin: Immediately wash skin with plenty water.  Consult physician if irritation persists.

Eye: Irrigate with flowing water immediately and continuously for 15 minutes.  Consult physician

Inhalation: Remove to fresh air.

Ingestion: Low in toxicity.  Induce vomiting if large amounts are ingested.

 

REACTIVITY DATA

Stability: Stable

Hazardous Polymerization: Will not occur

Incompatibility: Base


 

SPILL, DISPOSAL AND STORAGE INFORMATION

Spill: Soak in absorbent material such as sand or vermiculite.  Residual resin may be removed using steam or hot, soapy water.

Disposal: Burn in adequate incinerator or bury in landfill.  Consult federal, state and local regulations.

Storage: Store in cool dry place.

 

PROTECTIVE EQUIPMENT AND CONTROL MEASURES

Respiratory: None normally needed

Gloves: Rubber gloves

Eye: Safety glasses with or without side shields.

Ventilation: Local exhaust to minimize vapor if generated

 

SECTION 313 SUPPLIER NOTIFICATION

Not applicable.

 

{ { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { {

 

The information presented is believed to be correct and is the most accurate information available to us at this time.  However, Ladd Research makes no warranty, express or implied, and assumes no liability for this information and the product described herein.