MATERIAL SAFETY DATA SHEET

 

Product Name: Mechanical Pump Oil

Catalog Number: 30005

DOT Hazard Class: Not Hazardous

MSDS Updated: 9/16/05

 

Distributed By: Ladd Research

                             83 Holly Court

                             Suite 101

                             Williston, VT 05495

                             (802) 658-4961

 

HAZARDOUS COMPONENTS

No hazardous ingredients. Material is 100% neutral paraffinic oil. Material has been subjected to severe solvent refining.

 

US Government 8 hr TWA limit for exposure to oil mists is 5 mg/m³.

 

CAS [64742-54-7]

 

PHYSICAL AND CHEMICAL DATA

Boiling Point: >200E

Vapor Pressure: <0.001 Torr @ 25EC

Vapor Density: ~14

Specific Gravity: 0.87

Appearance and Odor: Pale yellow, viscous liquid with faint petroleum odor.

 

FIRE AND EXPLOSION HAZARD DATA

Flash Point: >213EC (Cleveland Open Cup)

Extinguishing Media: Water fog, chemical foam or carbon dioxide.

Special Fire Fighting Procedures: Wear breathing gear when fighting fires in enclosed spaces. Incomplete combustion of this material produces carbon monoxide.

 

HEALTH HAZARD DATA

Primary Routes of Entry: Inhalation and ingestion

Acute effects: Exposure to oil mists may cause nausea and eye irritation.  Detailed studies have not been made, but material is not expected to cause dermatitis or skin sensitization.

Chronic effects: Unknown

 

EMERGENCY AND FIRST AID

Skin: Wash with soap and water.

Eyes: Flush with plenty water.  Consult physician if irritation persists.

Ingestion: Give liquids and induce vomiting if victim is conscious. Small amounts in mouth may be washed out.

 

REACTIVITY DATA

Stability: Stable

Hazardous Polymerization: Will not occur

Conditions to Avoid: Continuous exposure to temperatures > 200EC.

Hazardous Decomposition Products: Incomplete combustion may product carbon monoxide.

 

SPILL, DISPOSAL AND STORAGE INFORMATION

Spill: Small spills may be wiped up with a rag.  Large spills should be picked up immediately with an absorbent.

Disposal: Proper waste disposal procedures are dependent on the product’s end use.  Check applicable federal, state and local laws covering treatment, storage and disposal of your process effluents.

 

PROTECTIVE EQUIPMENT AND CONTROL MEASURES

Respiratory: See notes on ventilation below.

Gloves: Made of oil-impermeable rubber.

Eye Wear: Glasses should have side shields.

Ventilation: US Government 8 hr TWA limit for exposure to oil mists is 5 mg/m³.  Local exhaust and mechanical exhaust to meet limit listed above.

 

SECTION 313 SUPPLIER NOTIFICATION

Not applicable.

 

v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v

 

The information presented is believed to be correct and is the most accurate information available to us at this time.  However, Ladd Research makes no warranty, express or implied, and assumes no liability for this information and the product described herein.