MATERIAL SAFETY DATA SHEET
Product Name: Conductive
Silver Epoxy (part A)
Catalog Number: 60802
part A (adhesive)
DOT Hazard Class: Not
Hazardous
MSDS Prepared: 9/2009
Distributed By: Ladd Research
83
Holly Court
Williston, VT 05495
(802) 658-4961
HAZARDOUS COMPONENTS
CAS Number
Percent Exposure Limits
Silver (metallic) 7440-22-4
60-90% 0.1 mg/m3 ACGIH TLV
0.1
mg/m3 OSHA PEL
Epoxy Resin 025068-38-6 10-25% NA
Modified Epoxy Ester mixture 1-3% NA
PHYSICAL AND CHEMICAL
DATA
Physical State: Silver/gray
paste
Odor: Mild
Vapor Pressure: <0.10
mmHg @ 20°C
Percent Volatile: <0.5%
Solubility in Water: <10%
Specific Gravity: 2.5-2.8
Evaporation Rate: <1
(butyl acetate=1)
Boiling Range: >200°F
FIRE AND EXPLOSION
HAZARD DATA
Flash Point: >200°F
Extinguishing Media: Use
carbon dioxide or dry chemicals for small fires, aqueous foam or water fog for
large fires involving this material.
Fire Fighting
Instructions: Remove all ignition sources. As in any fire, wear
self-contained breathing apparatus and full protective gear.
HEALTH HAZARD DATA
Eyes: Liquid
and vapors of this product may cause eye injury which may persist for several
days.
Skin: Contact
may cause reddening and swelling. Sensitizer – may cause allergic skin
reaction.
Ingestion: Harmful
if swallowed. Resin is slightly toxic. Silver ingestion may result in
generalized argyria.
Inhalation: No
specific information available.
Pre-Existing Medical Conditions Aggravated by
Exposure: Heart, lung, eye, skin
EMERGENCY AND FIRST AID
Eyes: Immediately
flush with large amounts of water. After initial flushing, remove any contact
lenses and continue flushing for at least 15 minutes. Have eyes examined by
physician.
Skin: Remove
contaminated clothing and wash skin with soap and water. Get medical attention
if irritation develops.
Ingestion: If
appreciable amounts are swallowed, seek medical attention.
Inhalation: In
case of exposure to high concentrations of vapor or mist, remove to fresh air.
If breathing is difficult, give oxygen and call a physician. If breathing has
stopped, apply artificial respiration and call a physician.
REACTIVITY DATA
Stability: Stable
under normal conditions.
Conditions to Avoid: Storage
above 120°F, exposure to light,
loss of dissolved air, loss of polymerization, inhibitor, contamination with
incompatible materials. Polymerization initiators including peroxides, strong
oxidizing agents, copper, copper alloys, carbon steel, iron, rust or strong
bases.
Incompatibility: Avoid
strong oxidizing agents, copper, copper alloys, carbon steel, iron and rust.
Avoid strong acids and bases. Also avoid caustics, amines, alkalis and
mercaptans.
Products of
Decomposition: Carbon monoxide, carbon dioxide.
Hazardous
Polymerization: May occur.
SPILL, DISPOSAL AND
STORAGE INFORMATION
Spills: Absorb
spill with absorbent material, then place in a chemical waste container for
proper disposal.
Disposal: Dispose
of in accordance with federal, state and local regulations.
Storage: Store
in a cool, dry place. Do not breathe vapor.
PROTECTIVE EQUIPMENT
AND CONTROL MEASURES
Good general ventilation
should be sufficient to control airborne levels. Local exhaust ventilation may
be necessary to control any air contaminants to within their TLV’s during the
use of this product. Wear safety
glasses with side shields or goggles and rubber or other chemically resistant
gloves when handling this material.
SECTION 313 SUPPLIER
NOTIFICATION
Not applicable.
v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v
The information presented is
believed to be correct and is the most accurate information available to us at
this time. However, Ladd Research makes
no warranty, express or implied, and assumes no liability for this information
and the product described herein.