MATERIAL SAFETY DATA SHEET
Product Name:
Conductive Silver Epoxy (part A)
Catalog
Number: 60802 part A (adhesive)
DOT Hazard
Class: Not Hazardous
MSDS
Prepared: 8/02
Distributed By: Ladd Research
83 Holly Court
Williston, VT 05495
(802) 658-4961
HAZARDOUS
COMPONENTS
CAS Number Percent Exposure
Limits
Silver (metallic) 7440-22-4
60-90% 0.1 mg/m3 ACGIH TLV
0.1
mg/m3 OSHA PEL
Epoxy Resin 025068-38-6 10-25% NA
Modified Epoxy Ester mixture 1-3% NA
PHYSICAL AND
CHEMICAL DATA
Physical
State: Silver/gray paste
Odor: Mild
Vapor
Pressure: <0.10 mmHg @ 20°C
Percent
Volatile: <0.5%
Solubility in
Water: <10%
Specific
Gravity: 2.5-2.8
Evaporation
Rate: <1 (butyl acetate=1)
Boiling
Range: >200°F
FIRE AND
EXPLOSION HAZARD DATA
Flash Point: >200°F
Extinguishing
Media: Use carbon dioxide or dry chemicals for small
fires, aqueous foam or water fog for large fires involving this material.
Fire Fighting
Instructions: Remove all ignition sources. As in any fire,
wear self-contained breathing apparatus and full protective gear.
HEALTH HAZARD
DATA
Eyes: Liquid and vapors of this product may cause eye injury which may
persist for several days.
Skin: Contact may cause reddening and swelling. Sensitizer – may cause
allergic skin reaction.
Ingestion: Harmful if swallowed. Resin is slightly toxic. Silver ingestion may
result in generalized argyria.
Inhalation: No specific information available.
Pre-Existing Medical Conditions Aggravated by
Exposure: Heart, lung, eye, skin
EMERGENCY AND
FIRST AID
Eyes: Immediately flush with large amounts of water. After initial flushing,
remove any contact lenses and continue flushing for at least 15 minutes. Have
eyes examined by physician.
Skin: Remove contaminated clothing and wash skin with soap and water. Get
medical attention if irritation develops.
Ingestion: If appreciable amounts are swallowed, seek medical attention.
Inhalation: In case of exposure to high concentrations of vapor or mist, remove to
fresh air. If breathing is difficult, give oxygen and call a physician. If
breathing has stopped, apply artificial respiration and call a physician.
REACTIVITY
DATA
Stability: Stable under normal conditions.
Conditions to
Avoid: Storage above 120°F, exposure to light, loss of dissolved air,
loss of polymerization, inhibitor, contamination with incompatible materials.
Polymerization initiators including peroxides, strong oxidizing agents, copper,
copper alloys, carbon steel, iron, rust or strong bases.
Incompatibility: Avoid strong oxidizing agents, copper, copper alloys, carbon steel,
iron and rust. Avoid strong acids and bases. Also avoid caustics, amines,
alkalis and mercaptans.
Products of
Decomposition: Carbon monoxide, carbon dioxide.
Hazardous
Polymerization: May occur.
SPILL,
DISPOSAL AND STORAGE INFORMATION
Spills: Absorb spill with absorbent material, then place in a chemical waste
container for proper disposal.
Disposal: Dispose of in accordance with federal, state and local regulations.
Storage: Store in a cool, dry place. Do not breathe vapor.
PROTECTIVE
EQUIPMENT AND CONTROL MEASURES
Good general
ventilation should be sufficient to control airborne levels. Local exhaust
ventilation may be necessary to control any air contaminants to within their
TLV’s during the use of this product.
Wear safety glasses with side shields or goggles and rubber or other
chemically resistant gloves when handling this material.
SECTION 313
SUPPLIER NOTIFICATION
Not applicable.
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v v
v
The information
presented is believed to be correct and is the most accurate information
available to us at this time. However,
Ladd Research makes no warranty, express or implied, and assumes no liability
for this information and the product described herein.